TDI Advanced Nitrox
Nitrox from 21% to 100% oxygen: deeper, longer and with accelerated decompression
Navigate using buttons, arrow keys or by swiping with your finger. Slides include charts, interactive tools and self-assessment questions.
1. Introduction
What is TDI Advanced Nitrox?
Advanced Nitrox allows the use of nitrox mixtures from 21% to 100% oxygen and dive up to 45 m.
- Requirements: Nitrox certification and experience (minimum number of dives according to TDI standards).
- Often learned together with Decompression Procedures.
- Goal: optimal mixture for every dive and oxygen for decompression.
Mixture range
2. Physics
Dalton's law in review
PO₂ = FO₂ × P, FO₂ = PO₂ / P, P = PO₂ / FO₂.
- EANx50 at 21 m depth: 0.5 × 3.1 = 1.55 bar.
- O₂ at 6 m depth: 1.0 × 1.6 = 1.6 bar.
- EANx28 at 40 m depth: 0.28 × 5 = 1.4 bar.
Dalton's triangle
Cover the value you are looking for: PO₂ on top, FO₂ and P on the bottom. The visible calculation is the answer.
3. Planning
Best mix for depth
Best mix at 1.4 bar
- Less oxygen for deeper dives.
- More oxygen for shallower dives, but above 40% you need oxygen-compatible equipment.
- Available mixes are often 28, 32, 36%.
4. Decompression
Nitrox for decompression
- Richer oxygen accelerates nitrogen elimination.
- Typical deco gases: EANx50 (from 21 m) and O₂ (from 6 m).
- During deco, PO₂ up to 1.6 bar.
- Carry deco gas in a stage cylinder with clear labelling.
MOD at 1.6 bar
4. Decompression
Oxygen window
- Oxygen used in tissues is replaced by CO₂, which dissolves better.
- Therefore, the total gas pressure in tissues is lower than the pressure of the inhaled gas.
- This difference (“oxygen window”) helps eliminate inert gas without bubble formation.
- Higher PO₂ during deco increases the window.
Practical
That is why oxygen at 6 m depth is so effective in decompression.
5. Physiology
CNS tracking
- Each PO₂ value has a time limit (NOAA table).
- CNS % = time at PO₂ / limit × 100.
- Sum the CNS of all diving phases.
- Goal: below 80% in a single dive.
NOAA limits
5. Physiology
CNS calculation example
Dive: 25 min at 1.4 bar and 12 min oxygen at 6 m (1.6 bar).
- 25 / 150 = 16,7%
- 12 / 45 = 26,7%
- Total: approx 43% CNS
CNS distribution
5. Physiology
Pulmonary toxicity
- OTU tracks pulmonary exposure above PO₂ 0.5 bar.
- Single day limit approx 850 OTU, for multiple days lower per day.
- Long decompression and multi-day trips require tracking.
⚠ Symptoms
Burning sensation in chest, cough, shortness of breath. Stop diving and consult a doctor.
6. Equipment
Oxygen compatible equipment
- Above 40% oxygen: equipment cleaned for oxygen and with compatible lubricants.
- Fire triangle: fuel (oil, dirt), oxygen, heat (adiabatic compression).
- Open the valve slowly to reduce heat due to compression.
- Do not use oxygen equipment for regular air from an unfiltered compressor.
Fire triangle
7. Gases
How mixtures are prepared
Partial pressure
Oxygen is added to the cylinder first, then filled with air. The cylinder must be oxygen clean.
Continuous flow
Oxygen is added to the compressor intake. Precise control with an analyzer.
Membrane
The membrane separates a portion of nitrogen from the air. Usually up to ~40%.
7. Gases
Analysis and labeling
- Each cylinder is analyzed by the diver themselves.
- Label: O₂ %, MOD, date, name.
- For stage cylinders, large MOD numbers on both sides.
- For oxygen cylinder: “O₂ 6 m”.
⚠ The cost of errors
An incorrectly labeled deco cylinder can cause seizures at depth.
8. Procedures
Gas switch protocol
9. Planning
Dive plan
- Bottom gas based on best mix and MOD
- Deco gases and switch depths
- CNS and OTU calculation
- Gas volume with reserve
- Contingency plans: deco gas loss, deeper, longer
- Emergency plan and surface oxygen
9. Planning
Diving to 45 m
- 45 m: absolute pressure 5.5 bar.
- EANx25 at 1.4 bar: MOD approx 46 m.
- Air PO₂ at 45 m: 1.16 bar, but END at 45 m.
- Narcosis and gas density determine practical limits.
PO₂ at 45 m depth
10. Problems
What can go wrong
Signs of toxicity
Switch immediately to a gas with lower PO₂, ascend shallower if possible.
Seizures in a buddy
Keep the regulator in the mouth, ascend in a controlled manner after the seizure.
Wrong gas
If noticed: switch back to the correct gas immediately.
Lack of deco gas
Contingency plan with bottom gas.
6. Equipment
Equipment for the course
Double cylinders
Or sidemount with two first stages.
Stage cylinder
For deco gas.
Analyzer
Oxygen sensor.
Computer
With multi-gas support.
Wetnotes
Plans and backup tables.
SMB
With a spool.
10. Problems
After diving
- Record gases, depths, times, CNS and OTU
- Hydration and rest
- Monitor for signs of DCS and pulmonary toxicity
- Rinse oxygen equipment and store it clean
- Check OTU accumulation for the next day
Debriefing
Discuss as a team what went well and what to do differently next time.
Self-check
Test yourself
What is the maximum depth for Advanced Nitrox?
What is the best mix for 40 m at 1.4 bar?
What is the CNS after 12 min of oxygen at 1.6 bar?
Why open the valve slowly?
Summary
O₂ mixes
maximum depth
always count
The material supplements the official TDI course materials and instructor-led training, but does not replace them.
