PADI Enriched Air Diver (Nitrox) – theory

PADI Enriched Air Diver (Nitrox) · theory material

PADI Enriched Air Diver

Diving with enriched air (Nitrox): from 22% to 40% oxygen

Navigate using buttons, arrow keys or by swiping with your finger. Slides include charts, interactive tools and self-assessment questions.

1. Introduction

What is enriched air?

Enriched air (Enriched Air Nitrox, EANx) is a mixture of nitrogen and oxygen containing more than 21%. The number after EANx indicates the oxygen percentage: EANx32 means 32% oxygen and 68% nitrogen.

  • The PADI Enriched Air Diver course covers mixtures with 22–40% oxygen.
  • The most common mixtures are EANx32 and EANx36.
  • Prerequisites: PADI (Junior) Open Water Diver, at least 12 years old.
  • The course can be completed via theory only or with 2 optional dives.
Nitrox is not intended for deeper diving. It allows you to dive safely longer at shallower depths.

Gas composition

The more oxygen, the less nitrogen: EANx32 has 68% N₂, air has 79% N₂.

2. Benefits and risks

Why dive with Nitrox?

Advantages

  • Longer no-decompression limits, because the body absorbs less nitrogen.
  • Shorter surface intervals between repetitive dives.
  • Greater safety margin when diving within air limits.

Risks

  • Oxygen toxicity, if the maximum PO₂ is exceeded.
  • Fire hazard and equipment requirements if oxygen content is higher than 40%.
  • Errors in gas analysis or computer settings.
Myth: Nitrox reduces fatigue and narcosis. Studies have not proven this. Narcosis risk should be evaluated the same as with air.

Equivalent Air Depth (EAD)

For example, with EANx32 at a depth of 24 m, the nitrogen load is the same as with air at a depth of ~19.3 m, therefore the no-decompression limit is significantly longer. Exact limits are determined by the EANx table or dive computer.

3. Physics

Partial pressure of oxygen (PO₂)

Dalton's Law: each gas in a mixture exerts pressure according to its proportion. PO₂ = FO₂ × absolute pressure.

ExampleCalculationPO₂
Air 30 m0,21 × 40.84 bar
EANx32 30 m0,32 × 41.28 bar
EANx32 34 m0,32 × 4,41.41 bar
EANx36 29 m0,36 × 3,91.40 bar
1.4 bar is the maximum PO₂ for planned dives. 1.6 bar is an emergency (contingency) limit that must not be exceeded.

PO₂ increase with depth

If the curve exceeds 1.4 bar, you must not dive that deep with this mixture.

3. Physics

Maximum Operating Depth (MOD)

MOD is the deepest depth at which the mixture's PO₂ does not yet exceed the selected limit.

MOD = (PO₂ ÷ FO₂ − 1) × 10

  • EANx32 at 1.4 bar: (1.4 ÷ 0.32 − 1) × 10 = 33.7 m
  • EANx36 at 1.4 bar: (1.4 ÷ 0.36 − 1) × 10 = 28.9 m
  • EANx40 at 1.4 bar: (1.4 ÷ 0.40 − 1) × 10 = 25 m
MOD must be written on the cylinder label and set in the dive computer as a warning.

MOD at 1.4 and 1.6 bar

At 1.6 bar (emergency): EANx32 40 m · EANx36 34 m · EANx40 30 m.

Interactive

MOD and EAD calculator

Enter the mixture, PO₂ limit, and planned depth. The calculator will show the MOD, PO₂ at depth, and equivalent air depth.

EAD (Equivalent Air Depth) is the depth at which you would have the same nitrogen load with air. It is used when planning a dive with air tables.

4. Physiology

Oxygen toxicity

CNS toxicity (central nervous system)

Occurs if PO₂ is high (above 1.4–1.6 bar). Can cause seizures without warning, which underwater usually means that the diver loses the regulator and drowns.

Possible symptoms (VENTID-C): Vision, Ears, Nausea, Twitching, Irritability, Dizziness, Convulsions.

Action: ascend to a shallower depth immediately and terminate the dive.

Pulmonary toxicity

Occurs if breathing elevated PO₂ for long periods, for example, during many dives over several days. Symptoms: burning sensation in the chest, coughing. In recreational diving, it is rare.

%CNS “clock”

The computer tracks oxygen toxicity in percentage of the allowable limit. Do not exceed 100% and plan with a reserve.

5. Procedures

Mixture analysis and labelling

1Receive the cylinder at the filling station
2Calibrate the analyzer with air (20.9%)
3Analyze the oxygen content yourself
4Compare with the label (±1%)
5Apply the % and MOD sticker, sign the log
6Set FO₂ on the computer

Cylinder labelling

  • Green-yellow band or “Enriched Air” / “Nitrox” label.
  • Sticker with oxygen %, MOD, date, and the name of the person who analyzed it.
  • Service sticker if the cylinder is oxygen-cleaned.

Fill log

Record the analyzed %, MOD, date, and cylinder number, and sign. By doing so, you certify that you have checked the mixture yourself.

If the analysis differs from the label by more than 1%, do not use the cylinder until the exact content is determined and recalculate the MOD.

6. Equipment

Equipment and oxygen

Up to 40% O₂

Most manufacturers allow standard regulators and cylinders. Always check the manufacturer's instructions.

Over 40% O₂

Equipment must be cleaned and prepared for oxygen service (oxygen service), with compatible lubricants and O-rings.

Computer

The computer must be set to the specific mixture (FO₂) and PO₂ limit before each dive. If this is not done, NDL and warnings will be incorrect.

Oxygen itself does not burn, but it strongly promotes combustion. Oil, grease, and dirt can ignite under high oxygen pressure.

7. Planning

Dive planning with Nitrox

  1. Choose the mixture based on depth (best mix: PO₂ 1.4 ÷ absolute pressure).
  2. Calculate the MOD and do not exceed it.
  3. Determine NDL using EANx tables, EAD and air tables, or a computer.
  4. Check the %CNS oxygen toxicity, especially for multi-day dives.
  5. Tell your buddy your mixture and MOD. Follow the shallower MOD.
  6. During descent, monitor depth to ensure you do not exceed the MOD.

Best mix for depth

At PO₂ 1.4 bar. In recreational diving, the oxygen fraction does not exceed 40%.

Physics

Dalton's Law

The partial pressure of each gas is its share of the total pressure:

Pgas = Fgas × Pabs

EANx32, 20 m (3 bar): PO₂ = 0.32 × 3 = 0.96 barPN₂ = 0.68 × 3 = 2.04 bar

The body absorbs nitrogen depending on PN₂. Less nitrogen in the mixture means less absorption.

Partial pressure of nitrogen

Planning

Equivalent Air Depth (EAD)

EAD shows what depth with air corresponds to the nitrogen load with Nitrox:

EAD = (FN₂ / 0.79) × (D + 10) − 10

EANx32, 30 m: (0.68/0.79) × 40 − 10 ≈ 24.4 m

So 30 m with EANx32 in terms of nitrogen is like ~24 m with air. Nowadays, the computer calculates this, but the principle must be understood.

Remember

EAD reduces nitrogen load, but does not change oxygen limits. MOD is still the deciding factor.

Gas

How Nitrox is mixed

Partial pressure method

Pure oxygen is added to the cylinder first, then topped up with air. Equipment must be oxygen-cleaned.

Membrane system

A membrane separates part of the nitrogen from the air before the compressor. The result is a mixture of up to ~40% O₂.

Premixed

Gas is mixed in large tanks and transferred to the cylinder. Consistent composition.

Nitrox filling is performed only by certified gas blenders. The diver must verify the content with an analyzer.

Oxygen

Oxygen exposure tracking

  • %CNS shows the central nervous system oxygen toxicity load as a percentage of the limit.
  • The computer calculates this automatically and warns when approaching the limit.
  • During the surface interval, %CNS gradually decreases.
  • In recreational diving with PO₂ up to 1.4 bar, %CNS rarely becomes the limiting factor, but multiple dives per day increase it.

%CNS throughout the day

Illustrative: three dives with surface intervals.

Planning

Repetitive dives with Nitrox

  • Less nitrogen accumulation means longer limits also on the second and third dive.
  • Shorter surface intervals are possible, but follow the computer's instructions.
  • For every dive, check the O₂ % set on your computer.
  • If you change the cylinder to a different mixture, analyze and reset it.

No-decompression limit at 18 m (approximate)

Illustrative for the first dive. Actual limits are determined by your computer or table.

Security

Nitrox myths and truth

“You can dive deeper with Nitrox”

No. Due to oxygen, the maximum depth is shallower than with air.

“Nitrox prevents narcosis”

No. Oxygen can also be narcotic, so the risk of narcosis should be assessed as with air.

“There is no fatigue with Nitrox”

Some divers feel less tired, but it has not been scientifically proven.

“Nitrox is only for professionals”

No. The course can be taken from the age of 12 with an Open Water certification.

Security

Common mistakes

  • Forgot to set O₂ % on the computer: computer calculates as with air or the previous mix
  • Cylinder not analyzed by yourself: relying on the sticker
  • MOD not discussed with the buddy
  • When diving with a buddy using a different mix, the stricter limit must be used for planning
  • Nitrox cylinder used as a regular air cylinder without changing the marking
  • Depth limit exceeded while following the buddy

Self-check

Test yourself: calculations

PO₂ with EANx36 at 25 m depth?

EAD with EANx32 at 30 m depth?

What does %CNS show?

What must be done before every dive with nitrox?

Self-check

Test yourself

What is the MOD with EANx36 at 1.4 bar?

Who analyzes the mixture in the cylinder?

What is the main advantage of Nitrox?

What is the greatest risk of CNS toxicity?

Summary

1.4 bar

max PO₂ for planned dives

±1%

allowable analysis difference

MOD

on each cylinder and in the computer

Take the PADI Enriched Air Diver test →

This material supplements the official PADI course materials and instructor-led training, but does not replace them.