JJ-CCR MOD 1 – Helitrox – theory

JJ-CCR Helitrox · theory material

JJ-CCR MOD 1 – Helitrox

Helium in diluent: reduced narcosis down to 45 m

Navigate using buttons, arrow keys or by swiping with your finger. Slides include charts, interactive tools and self-assessment questions.

1. Introduction

What is Helitrox CCR?

  • Max. depth: 45 m.
  • Diluent: Helitrox: normoxic trimix with limited helium, e.g., 21/35.
  • Goal: reduced narcosis and easier breathing.
  • Requirements: MOD 1 Air Diluent (and usually deco course) according to agency standards.
  • Precise O₂/He limits are set by TDI standards.

Depth by courses

2. Gases

Properties of helium

  • Non-narcotic at practical depths.
  • Lightweight: reduces gas density and work of breathing.
  • Fast diffusion: absorbs and releases from tissues faster.
  • Thermal conductivity: not used for skin and drysuit (argon or air is used for suit inflation).
  • Expensive: CCR consumption makes it cost-effective.

Gas density at surface, g/l

3. Narcosis

Equivalent Narcotic Depth (END)

  • END shows the air depth equivalent to the narcosis experienced.
  • Nitrogen END: (depth + 10) × N₂ fraction / 0.79 − 10.
  • With 21/35 diluent at 45 m depth: N₂ = 0.44.
  • (55 × 0.44 / 0.79) − 10 ≈ 21 m.

END at 45 m depth (N₂ only)

4. Narcosis

Is oxygen narcotic?

  • Many agencies assume that oxygen is also narcotic.
  • Then END is calculated using O₂ + N₂.
  • CCR high setpoint adds oxygen to the loop.
  • Conservative calculation gives a higher END.

Why does CCR END differ from OC?

The PO₂ in the loop is constant, so the inert gas ratio changes with depth. The computer calculates the real END using the diluent composition and setpoint.

5. Breathing

Gas density and CO₂

  • Dense gas increases the work of breathing.
  • Higher work of breathing means more CO₂ in the blood.
  • Recommended density: up to 5.2 g/l, maximum 6.2 g/l.
  • Helium allows staying below these limits.

Density at 45 m, g/l (approximate)

6. Gases

Diluent mixing and analysis

  • Helitrox is mixed using the partial pressure method or a gas blender.
  • Every cylinder is analyzed for O₂ and He.
  • Mark: O₂%, He%, MOD, date, analyzer.
  • Enter the diluent composition into the controller.

⚠ Analysis

Incorrect diluent composition in the controller means incorrect deco calculation and END. Analyze it yourself.

7. Bailout

Bailout with helium

  • Bailout gas is usually the same as the diluent or a similar trimix.
  • With it, narcosis at 45 m depth is lower.
  • Add deco gas for stops, e.g., EAN50.
  • Calculate gas for stress breathing.

Bailout gas consumption (illustrative)

8. Decompression

Decompression with helium

  • Helium is absorbed faster, but also released faster.
  • For short dives, deco can be similar or slightly longer.
  • For longer dives, the benefit is a clearer head.
  • At shallow stops, helium is released quickly.

Practice

Do not compare only deco minutes: a clear mind at 45 m depth is the biggest safety benefit.

9. Breathing

Heat and helium

  • Helium conducts heat better than air.
  • The CCR loop is warm and humid, so breathing does not cool you down as much.
  • Do not fill the drysuit with helium.
  • Bailout breathing with trimix cools you down faster.

Recommendation

In Baltic waters, use a heated vest or warm undergarments and argon for suit inflation.

10. Planning

Helitrox dive plan

  • Diluent composition and MOD.
  • Setpoint during the bottom phase and at stops.
  • Deco plan with GF and bailout plan.
  • Scrubber time and water temperature.
  • Team decision points and turn pressure.

Example

ParameterValue
Depth42 m
Diluent21/35
Setpoint0,7 / 1,3
GF30/75
Bailout21/35 + EAN50

11. Loop

Diluent flush with trimix

  • At 45 m depth, the PO₂ of 21/35 diluent is 1.16 bar.
  • Safe for flushing at all course depths.
  • After flushing, the sensors should show the expected value.
  • At shallow depths (above ~6 m), the diluent PO₂ can be below 0.4.

21/35 diluent PO₂

12. Problem solving

Problem solving at depth

  • High PO₂: diluent flush.
  • Low PO₂: manual O₂ addition.
  • Sensor mismatch: diluent or O₂ flush for validation.
  • CO₂ or water in the loop: bailout.
  • Electronics failure: manual control or bailout.

Clear head

Less narcosis means faster and more accurate problem solving. This is the main goal of Helitrox.

13. Team

Team and communication

  • All team divers know each other's gases.
  • Bailout gas can be shared.
  • After bailout, the team ascends together according to the bailout plan.
  • Support team on the boat knows the deco time.

Decision

Any team member can abort the dive at any time without explanation.

14. Development

Path to MOD 2

  • After Helitrox: experience and diving to 45 m depth.
  • MOD 2: normoxic trimix down to 60 m.
  • Multiple deco cylinders and more complex bailout plans.
  • MOD 3: hypoxic trimix to 100 m.

CCR path

15. x

Checks before Helitrox diving

  • Diluent analyzed for O₂ and He, marked.
  • Correct diluent entered into the controller.
  • Bailout trimix and deco gas analyzed.
  • Pressure tests and cell calibration.
  • Pre-breathe for 3–5 minutes.

Computer

If “air” remains in the computer as diluent, deco and END calculations will be incorrect.

16. x

Descent with Helitrox diluent

  • ADV adds diluent: helium fraction increases in the loop.
  • Switch to high setpoint according to plan.
  • Check PO₂ and cell agreement at 6–10 m depth.
  • Control buoyancy with the wing.

Loop composition at 45 m at PO₂ 1.3 (approximately)

17. x

Ascent and stops

  • Ascend no faster than 9 m/min, even slower at stops.
  • PO₂ drops, solenoid adds O₂.
  • At 6 m depth, O₂ flush can be used to accelerate deco.
  • In the last few meters, watch for hypoxia risk.

⚠ On the surface

Before closing the DSV, ensure PO₂ is safe, and close the DSV before removing from mouth.

Self-check

Test yourself

What is the maximum depth for Helitrox CCR?

What is the approximate END at 45 m depth with 21/35?

Why does helium reduce the work of breathing?

What should you not fill a drysuit with?

Summary

45 m

maximum depth

21 m

END with 21/35

He

less narcosis

Book JJ-CCR Helitrox test →