JJ-CCR MOD 1 – Air Diluent Decompression
Decompression diving with a rebreather to 40 m, using air as a diluent
Navigate using buttons, arrow keys or by swiping with your finger. Slides include charts, interactive tools and self-assessment questions.
1. Introduction
What is Air Diluent Decompression?
- Max. depth: 40 m.
- Diluent: air.
- New: planned decompression stops.
- Requirements: MOD 1 Air Diluent and CCR experience according to agency standards.
- Prepares for MOD 1 Helitrox and MOD 2 courses.
Depth by courses
2. CCR and decompression
Why is CCR advantageous for decompression?
- Constant PO₂ means optimal gas at every depth.
- In the shallows, the inert gas fraction is lower than in open circuit.
- Shorter decompression than with air in open circuit.
- Low gas consumption: deco time does not empty cylinders.
Inert gas fraction at PO₂ 1.3 (illustrative)
3. Decompression
Decompression basics
- Tissues absorb nitrogen proportionally to its partial pressure.
- When ascending, gas must be allowed to release in a controlled manner: stops.
- Use an algorithm, e.g., Bühlmann with gradient factors (GF).
- Conservative GF, e.g., 30/70 or 40/80.
What does GF 30/70 mean?
The first stop starts at 30% of the M-value, at the surface 70% is allowed. Smaller numbers mean a more conservative plan.
4. Physiology
Narcosis and density at 40 m depth
- With air diluent, the END at 40 m depth is almost 40 m.
- Narcosis affects decision-making and problem-solving.
- Gas density for air at 40 m is about 6.4 g/l, exceeding the recommended 5.2 g/l.
- Therefore, 40 m is the limit for air diluent.
Air density, g/l
5. Planning
Dive plan
- Depth, bottom time, setpoint, GF.
- Decompression schedule and its backup plan.
- Scrubber used time and remaining time.
- Bailout gas for decompression if the loop fails.
- Team communication and decision points.
Plan with a reserve
Take two schedules with you: CCR plan and open-circuit bailout plan. Bailout deco is always longer.
6. Planning
Scrubber duration
- Use the manufacturer's specified scrubber time and reduce it in cold water.
- Keep track of the time used for each dive.
- Decompression diving extends the total time.
- Never plan a dive that exceeds the remaining time.
Scrubber time (illustrative)
7. Bailout
Bailout decompression
- Bailout gas must be sufficient for both ascent and stops.
- Open-circuit decompression with air is longer.
- Often two cylinders are used: bottom bailout and deco gas (e.g., EAN50).
- Bailout cylinders must be carried with you, not left on the line.
Deco time: CCR vs bailout (illustrative)
8. Bailout
Bailout to deco gas
EAN50 MOD
At PO₂ 1.6: 1.6 / 0.5 = 3.2 bar, so 22 m. Use 21 m or shallower.
9. Stops
Loop management at stops
- Maintain precise depth: ascending at stops changes PO₂.
- Usually at shallow depths the setpoint remains high (1.2–1.3).
- At 6 m depth, oxygen flush can be used to accelerate deco.
- During the last stop, check bailout and SMB.
O₂ flush at 6 m
With pure oxygen at 6 m depth, PO₂ is 1.6 bar. Keep flush short and monitor CNS load.
10. Physiology
Oxygen exposure
- Track CNS% and OTU.
- Long bottom time with high setpoint increases CNS.
- Limit CNS to around 80% within a single day.
- The computer calculates this, but understand how.
CNS% per minute at PO₂
11. Ascent
DSMB and ascent
- Deploy DSMB from the first stop or bottom.
- During deployment, control the loop and buoyancy.
- Ensure the reel does not tangle around the equipment.
- Ascend according to the plan, checking PO₂.
⚠ Attention
When inflating the DSMB with loop gas, the loop volume decreases and diluent may be added. Monitor PO₂.
12. Problem solving
Common problems
| Problem | Action |
|---|---|
| High PO₂ | Diluent flush, check solenoid |
| Low PO₂ | Add O₂ manually, check O₂ cylinder |
| Cell disagreement | Diluent flush and check |
| Signs of CO₂ | Bailout |
| Flooded loop | Bailout |
Principle
If the problem cannot be solved quickly and safely, switch to open circuit and terminate the dive.
13. Troubleshooting
Controller failure
- JJ-CCR can also be operated manually (in mCCR mode).
- Manually add O₂ to maintain PO₂.
- If there is no reliable PO₂ reading, switch to bailout.
- Backup computer for deco information.
Backups
Two independent PO₂ readings (e.g., wrist computer and HUD) are the minimum requirement.
14. Team
Team diving
- Agree on the plan and signals before the dive.
- Know your buddy's bailout configuration.
- If one buddy switches to bailout, both must terminate the dive.
- Gas sharing: bailout cylinders can be handed to a buddy.
Signals
Agree on signals for "PO₂ high", "PO₂ low", "bailout" and "CO₂".
15. Local practice
CCR diving in the Baltic
- Cold water reduces scrubber efficiency.
- Wrecks at 30–40 m depth are ideal for this course.
- Warm and moist loop gas reduces heat loss.
- Oxygen and communication must be available on the boat.
Recommendation
In cold water, use reserve scrubber time and drysuit heating.
16. Maintenance
After diving
- Log the scrubber usage time.
- Rinse the counterlungs and mouthpiece, disinfect.
- Check for water in the loop.
- Unload and store sensors correctly.
- Fill O₂ and diluent cylinders.
Disinfection
Use the agent recommended by the manufacturer. The loop is moist and warm, so bacteria multiply easily in it.
17. Planning
Deco dive checks
- Full assembly and pressure test check.
- Cells calibrated, pre-breathe 3–5 min.
- Bailout and deco gases analyzed and marked.
- GF, diluent and bailout gases entered into computers.
- Remaining scrubber time is sufficient with a reserve.
- Team briefing: plan, signals, decision points.
Briefing
Before every deco dive, the team agrees on the maximum depth, bottom time, and actions in case of bailout.
Self-check
Test yourself
What is the maximum depth for Air Diluent Decompression?
Why is 40 m the limit for air diluent?
What is the MOD of EANx50 at a PO₂ of 1.6?
What happens to the deco time if you have to switch to bailout?
Summary
maximum depth
conservative plan
deco gas
This material supplements the official TDI course materials, the JJ-CCR manufacturer's operating manual, and instructor-led training, but does not replace them.