1. Introduction

What is MOD 1 – Air Diluent?

  • Max. depth: 30 m, no-decompression.
  • Diluent: air.
  • Equipment: JJ-CCR electronically controlled closed-circuit rebreather.
  • Content: assembly, pre-dive checks, loop management, bailout procedures.
  • The first step towards decompression and trimix CCR courses.

CCR course depths

2. How CCR works

Closed-circuit principle

  • Exhaled gas is not released into the water, but returns to the loop.
  • Scrubber absorbs CO₂.
  • Solenoid adds oxygen to maintain the set PO₂ (setpoint).
  • Diluent fills the loop volume when diving deeper.
  • Consumes only metabolized oxygen: approximately 1 l/min at rest.

Loop path

1Mouthpiece (DSV/BOV)
2Exhalation counterlung
3Scrubber: CO₂ is absorbed
4O₂ sensors and solenoid
5Inhale counterlung
6Back to mouthpiece

3. JJ-CCR construction

JJ-CCR main parts

  • Head: three O₂ sensors, solenoid, electronics.
  • Scrubber canister with CO₂ absorbent.
  • Counterlungs on shoulders/chest with ADV and dump valve (OPV).
  • Mouthpiece with one-way valves.
  • Two small cylinders: oxygen and diluent.
  • Controllers: primary handheld computer and HUD.

JJ-CCR features

Danish design with CE certificate (EN 14143). Durable metal housing, easy to maintain. Electronics are usually provided by Shearwater controllers.

4. Physiology

Partial pressure and setpoint

  • A constant PO₂ is maintained in the loop, not a constant gas fraction.
  • Low setpoint around 0.7 bar: at the surface and during descent.
  • High setpoint usually 1.2–1.3 bar: during the bottom phase.
  • Safe zone: 0.16–1.6 bar.

PO₂ limits

5. Physiology

Three main CCR risks

Hypoxia

PO₂ below 0.16. Usually during ascent or with oxygen turned off. No warning: loss of consciousness.

Hyperoxia

PO₂ above 1.6. Risk: CNS toxicity and seizures.

Hypercapnia

CO₂ buildup: exhausted scrubber, water in the loop, faulty valves.

Golden rule

Always know your PO₂. Check it at every step: before the dive, during descent, in the bottom phase, and during ascent.

6. Diluent

Why is the diluent air?

  • Air is available, cheap, and breathable at the surface.
  • At a depth of 30 m, the PO₂ of air diluent is 0.84 bar: safe for diluent flushes.
  • Narcosis is like in open circuit with air.
  • Gas density limits the depth.

PO₂ of air at depth

7. Assembly

Equipment assembly

  • Scrubber filled according to instructions, settled, with the correct seal.
  • O-rings checked, clean, and lubricated.
  • Mouthpiece one-way valves checked.
  • Cylinders full, analyzed, and marked.
  • Hoses connected correctly: O₂ and diluent are not swapped.
  • Controllers turned on, batteries charged.

⚠ Checklist

Always use a written checklist for CCR assembly, even after hundreds of dives. Most accidents start with a skipped step.

8. Pre-dive

Pressure tests

  • Negative pressure test: suck air out of the loop, it must remain collapsed. Checks for leaks.
  • Positive pressure test: inflate the loop, it must remain inflated.
  • Valve test: inhalation and exhalation only in the correct direction.
  • Test time is usually about 1 minute for each.

Why is it important?

A leak allows water to enter the scrubber and creates a risk of getting a caustic cocktail or CO₂ problems.

9. Before diving

O₂ sensor calibration

  • Flush the loop with 100% oxygen.
  • Calibrate on the surface: PO₂ around 0.98–1.0 bar depending on atmospheric pressure.
  • All three cells must show similar readings.
  • Cells age: slow response or inaccurate reading means replacement.
  • Observe the cell expiration date.

Sensor voting

10. Before diving

Pre-breathe

  • Before diving, breathe from the loop for at least 3–5 minutes.
  • Observe if the solenoid adds oxygen and PO₂ is stable.
  • Listen to yourself: shortness of breath, headache, anxiety can indicate CO₂.
  • Pre-breathing does not reveal all scrubber problems.

⚠ Attention

Perform pre-breathing in a safe place: sitting down and with a buddy nearby. If you lose consciousness on the boat, it is dangerous.

11. Loop management

Descent and PO₂

  • During descent, the gas in the loop compresses: the ADV adds diluent.
  • PO₂ rises momentarily because the pressure increases.
  • At shallow depths, the setpoint is low (0.7).
  • Switch to high setpoint at a specific depth or automatically.
  • Control loop volume: not too much, not too little.

PO₂ in the dive profile (illustrative)

12. Loop management

Bottom phase

  • Check PO₂ every few minutes.
  • Compare all three cells.
  • Control buoyancy with the wing, not the loop.
  • Maintain minimal loop volume for comfortable breathing.

Habit

“Look, check, compare”: every 3–5 minutes look at the PO₂, check the cells and compare with the HUD.

13. Loop management

Ascent and hypoxia risk

  • During ascent, pressure drops, so PO₂ decreases.
  • The solenoid adds O₂, but a fast ascent can outpace it.
  • Ascend slowly, no faster than 9 m/min.
  • In the last 6 m, ascend even slower.
  • If necessary, add O₂ manually.

⚠ Danger zone

The highest risk of hypoxia is in the last few meters and at the surface. Before closing the DSV, verify the PO₂.

14. Troubleshooting

Diluent flush

  • Flush the loop with diluent: known PO₂.
  • Use if you suspect a sensor error or have an unclear PO₂.
  • 30 m with air: PO₂ after flushing is around 0.84.
  • After flushing, check if the sensors show the expected value.

Question: what will the PO₂ be after an air flush at a depth of 20 m?

3 bar × 0.21 = 0.63 bar.

15. Bailout

Bailout: open circuit

  • Bailout is an independent open-circuit cylinder with a regulator.
  • If you cannot trust the loop, switch to bailout.
  • “When in doubt, bailout.”
  • In the MOD 1 course, usually one bailout cylinder (e.g., 7 l or 11 l).
  • Bailout must be sufficient from the deepest point to the surface.

Bailout gas from 30 m, l (illustrative)

16. Bailout

Bailout gas calculation

  • Use stress breathing consumption: e.g., 20–25 l/min.
  • Calculate: problem solving at depth, ascent, stops.
  • Add a reserve.
  • Check if cylinder volume × pressure is sufficient.

Example

Stagel
1 min 30 m (4 bar × 25)100
Ascent ~3 min (avg. 2.5 bar × 25)190
3 min 5 m (1.5 bar × 25)110
Total400

7 l × 200 bar = 1400 l. Sufficient if reserve is observed.

17. Problem solving

Hypercapnia and the caustic cocktail

  • CO₂ signs: shortness of breath, headache, panic.
  • Action: switch to bailout, terminate the dive.
  • Caustic cocktail: water + absorbent creates an alkaline liquid.
  • If you feel a burning taste in your mouth: switch to bailout immediately.

⚠ CO₂

Hypercapnia cannot be fixed by flushing with diluent or oxygen: the problem is caused by the scrubber or valves. The only safe action is to switch to bailout.

Self-check

Test yourself

What is the maximum depth for MOD 1 Air Diluent?

What does the scrubber absorb?

When is the risk of hypoxia the greatest?

How to act if CO₂ is suspected?

Summary

30 m

maximum depth

3

O₂ sensors

Bailout

if in doubt

Take the JJ-CCR MOD 1 Air Diluent test →