1. Introduction
What is MOD 1 – Air Diluent?
- Max. depth: 30 m, no-decompression.
- Diluent: air.
- Equipment: JJ-CCR electronically controlled closed-circuit rebreather.
- Content: assembly, pre-dive checks, loop management, bailout procedures.
- The first step towards decompression and trimix CCR courses.
CCR course depths
2. How CCR works
Closed-circuit principle
- Exhaled gas is not released into the water, but returns to the loop.
- Scrubber absorbs CO₂.
- Solenoid adds oxygen to maintain the set PO₂ (setpoint).
- Diluent fills the loop volume when diving deeper.
- Consumes only metabolized oxygen: approximately 1 l/min at rest.
Loop path
3. JJ-CCR construction
JJ-CCR main parts
- Head: three O₂ sensors, solenoid, electronics.
- Scrubber canister with CO₂ absorbent.
- Counterlungs on shoulders/chest with ADV and dump valve (OPV).
- Mouthpiece with one-way valves.
- Two small cylinders: oxygen and diluent.
- Controllers: primary handheld computer and HUD.
JJ-CCR features
Danish design with CE certificate (EN 14143). Durable metal housing, easy to maintain. Electronics are usually provided by Shearwater controllers.
4. Physiology
Partial pressure and setpoint
- A constant PO₂ is maintained in the loop, not a constant gas fraction.
- Low setpoint around 0.7 bar: at the surface and during descent.
- High setpoint usually 1.2–1.3 bar: during the bottom phase.
- Safe zone: 0.16–1.6 bar.
PO₂ limits
5. Physiology
Three main CCR risks
Hypoxia
PO₂ below 0.16. Usually during ascent or with oxygen turned off. No warning: loss of consciousness.
Hyperoxia
PO₂ above 1.6. Risk: CNS toxicity and seizures.
Hypercapnia
CO₂ buildup: exhausted scrubber, water in the loop, faulty valves.
Golden rule
Always know your PO₂. Check it at every step: before the dive, during descent, in the bottom phase, and during ascent.
6. Diluent
Why is the diluent air?
- Air is available, cheap, and breathable at the surface.
- At a depth of 30 m, the PO₂ of air diluent is 0.84 bar: safe for diluent flushes.
- Narcosis is like in open circuit with air.
- Gas density limits the depth.
PO₂ of air at depth
7. Assembly
Equipment assembly
- Scrubber filled according to instructions, settled, with the correct seal.
- O-rings checked, clean, and lubricated.
- Mouthpiece one-way valves checked.
- Cylinders full, analyzed, and marked.
- Hoses connected correctly: O₂ and diluent are not swapped.
- Controllers turned on, batteries charged.
⚠ Checklist
Always use a written checklist for CCR assembly, even after hundreds of dives. Most accidents start with a skipped step.
8. Pre-dive
Pressure tests
- Negative pressure test: suck air out of the loop, it must remain collapsed. Checks for leaks.
- Positive pressure test: inflate the loop, it must remain inflated.
- Valve test: inhalation and exhalation only in the correct direction.
- Test time is usually about 1 minute for each.
Why is it important?
A leak allows water to enter the scrubber and creates a risk of getting a caustic cocktail or CO₂ problems.
9. Before diving
O₂ sensor calibration
- Flush the loop with 100% oxygen.
- Calibrate on the surface: PO₂ around 0.98–1.0 bar depending on atmospheric pressure.
- All three cells must show similar readings.
- Cells age: slow response or inaccurate reading means replacement.
- Observe the cell expiration date.
Sensor voting
10. Before diving
Pre-breathe
- Before diving, breathe from the loop for at least 3–5 minutes.
- Observe if the solenoid adds oxygen and PO₂ is stable.
- Listen to yourself: shortness of breath, headache, anxiety can indicate CO₂.
- Pre-breathing does not reveal all scrubber problems.
⚠ Attention
Perform pre-breathing in a safe place: sitting down and with a buddy nearby. If you lose consciousness on the boat, it is dangerous.
11. Loop management
Descent and PO₂
- During descent, the gas in the loop compresses: the ADV adds diluent.
- PO₂ rises momentarily because the pressure increases.
- At shallow depths, the setpoint is low (0.7).
- Switch to high setpoint at a specific depth or automatically.
- Control loop volume: not too much, not too little.
PO₂ in the dive profile (illustrative)
12. Loop management
Bottom phase
- Check PO₂ every few minutes.
- Compare all three cells.
- Control buoyancy with the wing, not the loop.
- Maintain minimal loop volume for comfortable breathing.
Habit
“Look, check, compare”: every 3–5 minutes look at the PO₂, check the cells and compare with the HUD.
13. Loop management
Ascent and hypoxia risk
- During ascent, pressure drops, so PO₂ decreases.
- The solenoid adds O₂, but a fast ascent can outpace it.
- Ascend slowly, no faster than 9 m/min.
- In the last 6 m, ascend even slower.
- If necessary, add O₂ manually.
⚠ Danger zone
The highest risk of hypoxia is in the last few meters and at the surface. Before closing the DSV, verify the PO₂.
14. Troubleshooting
Diluent flush
- Flush the loop with diluent: known PO₂.
- Use if you suspect a sensor error or have an unclear PO₂.
- 30 m with air: PO₂ after flushing is around 0.84.
- After flushing, check if the sensors show the expected value.
Question: what will the PO₂ be after an air flush at a depth of 20 m?
3 bar × 0.21 = 0.63 bar.
15. Bailout
Bailout: open circuit
- Bailout is an independent open-circuit cylinder with a regulator.
- If you cannot trust the loop, switch to bailout.
- “When in doubt, bailout.”
- In the MOD 1 course, usually one bailout cylinder (e.g., 7 l or 11 l).
- Bailout must be sufficient from the deepest point to the surface.
Bailout gas from 30 m, l (illustrative)
16. Bailout
Bailout gas calculation
- Use stress breathing consumption: e.g., 20–25 l/min.
- Calculate: problem solving at depth, ascent, stops.
- Add a reserve.
- Check if cylinder volume × pressure is sufficient.
Example
| Stage | l |
|---|---|
| 1 min 30 m (4 bar × 25) | 100 |
| Ascent ~3 min (avg. 2.5 bar × 25) | 190 |
| 3 min 5 m (1.5 bar × 25) | 110 |
| Total | 400 |
7 l × 200 bar = 1400 l. Sufficient if reserve is observed.
17. Problem solving
Hypercapnia and the caustic cocktail
- CO₂ signs: shortness of breath, headache, panic.
- Action: switch to bailout, terminate the dive.
- Caustic cocktail: water + absorbent creates an alkaline liquid.
- If you feel a burning taste in your mouth: switch to bailout immediately.
⚠ CO₂
Hypercapnia cannot be fixed by flushing with diluent or oxygen: the problem is caused by the scrubber or valves. The only safe action is to switch to bailout.
Self-check
Test yourself
What is the maximum depth for MOD 1 Air Diluent?
What does the scrubber absorb?
When is the risk of hypoxia the greatest?
How to act if CO₂ is suspected?