JJ-CCR MOD 3 – Advanced Mixed Gas / Hypoxic Trimix – theory

JJ-CCR MOD 3 · theory material

JJ-CCR MOD 3 – Advanced Mixed Gas / Hypoxic Trimix

Advanced level rebreather training up to 100 m with hypoxic trimix

Navigate using buttons, arrow keys or by swiping with your finger. Slides include charts, interactive tools and self-assessment questions.

1. Introduction

What is MOD 3?

  • Max. depth: 100 m.
  • Diluent: hypoxic trimix, e.g., 10/70.
  • Bailout: multiple cylinders: bottom trimix, travel gas, and deco gases.
  • Decompression: hours long.
  • Requirements: MOD 2 and significant experience at 50–60 m depth according to agency standards.

CCR course depths

2. Gases

Hypoxic diluent

  • Hypoxic gas contains less than ~16–18% O₂.
  • 10/70 at the surface: PO₂ 0.10 bar: not breathable!
  • Breathable only deeper than ~6 m (0.16 bar).
  • At 100 m depth: PO₂ = 11 × 0.10 = 1.1 bar.

10/70 PO₂ at depth

3. Gases

Risk of hypoxic diluent at the surface

  • At the surface, the CCR loop must not be flushed with hypoxic diluent.
  • At the start of the descent, the setpoint and solenoid maintain PO₂.
  • Often a travel diluent is used or the diluent is switched at depth.
  • Before diving, check that the correct diluent is in the controller.

⚠ Hypoxia

Flushing the diluent at the surface with 10/70 gives a PO₂ of about 0.1: loss of consciousness within a few breaths.

4. Narcosis

Narcosis and END 100 m

  • With 10/70 at 100 m depth, N₂ is 20%.
  • END (N₂) = 110 × 0.2 / 0.79 − 10 ≈ 18 m.
  • A clear head is mandatory for complex procedures.
  • CCR setpoint affects the actual inert gas fraction in the loop.

END 100 m (N₂ only)

5. Breathing

Gas density at 100 m

  • 10/70 at 100 m depth: approx. 5.7 g/l.
  • Close to the recommended limit.
  • Higher helium content reduces density.
  • Slow, deep breathing reduces CO₂ accumulation.

Density at 100 m, g/l (approx.)

6. Breathing

HPNS and descent

  • High Pressure Nervous Syndrome: tremors, nausea, concentration issues.
  • Mainly deeper than ~150 m, but rapid descent can trigger symptoms earlier.
  • Controlled descent rate.
  • If symptoms appear, stop or ascend.

Recommendation

At 100 m depth, descent usually takes several minutes. Rushing provides no benefit.

7. Decompression

Isobaric Counter-Diffusion (ICD)

  • When switching from a helium-rich gas to a nitrogen-rich one, gases can diffuse in opposite directions.
  • Risk: inner ear DCS.
  • “Rule of fifths”: N₂ fraction increase ≤ 1/5 of He fraction decrease.
  • Plan bailout gases so that transitions are gradual.

Switching from 10/70 to EAN50: does it fit the rule of fifths?

He decreases by 70 points (70 / 5 = 14), N₂ increases by 30 points (20 → 50). 30 > 14, so the transition is too abrupt. Plan gases and transition depths so that the N₂ increase is gradual, and verify with planning software.

8. Bailout

Bailout configuration

  • Bottom bailout: hypoxic trimix.
  • Travel gas: e.g., 21/35 or 18/45.
  • Deco gases: EAN50 and 100% O₂.
  • Often 3–5 cylinders on the side.
  • The team can share bailout and use staged cylinders.

Bailout gases (illustrative)

9. Bailout

Bailout gas volume

  • At 100 m depth consumption is 11 × surface consumption.
  • At 25 l/min: 275 l per minute.
  • 4 minutes to resolve the problem: approx. 1100 l.
  • Therefore, the deepest bailout cylinder is usually 11–12 l or larger.

Gas consumption per minute, l (25 l/min at surface)

10. Decompression

Long decompression

  • 20 min at 100 m depth can mean 2–3 h of deco.
  • Start of stops deep, around 50–60 m.
  • Thermal protection and hydration.
  • Deco team and line system.

Total dive time (illustrative)

11. Equipment

Scrubber for long dives

  • Long deco uses a large portion of scrubber time.
  • In cold water, efficiency drops.
  • Do not plan a dive close to the scrubber time limit.
  • The bailout plan assumes that the scrubber may fail.

⚠ Time

If the total planned time exceeds the manufacturer's recommendations, the dive is split or additional bailout is used.

12. Team

Support team and logistics

  • Support divers at stops: gas, assistance.
  • Oxygen, first aid, communication on the boat.
  • Evacuation plan and hyperbaric chamber.
  • Written plan for each team member.

Logistics

MOD 3 diving is a project, not a simple recreational dive: it requires planning and support.

13. Equipment

Electronics and backups

  • Two independent controllers with PO₂ and deco.
  • Backup deco plan on a slate.
  • Batteries fully charged and tested.
  • Cells new and tested at higher PO₂.

Cell check

Cell linearity is checked at PO₂ above 1.0, e.g., by flushing with O₂ at a depth of 6 m.

14. Troubleshooting

Critical situations at 100 m

SituationAction
CO₂ at depthBailout to bottom trimix, start ascent
Diluent lossOff-board diluent from bailout
O₂ lossLower setpoint, bailout deco
Electronics failureBackup computer, manual control, bailout

Principle

At depth, every minute costs a lot of gas. Act quickly and according to the plan.

15. Readiness

Physical and mental readiness

  • Good physical condition and health.
  • Regular practice at depth before MOD 3.
  • Training in bailout procedures.
  • Ability to call a dive.

Experience

MOD 3 is not the first deep dive: it is a step after several dives to a depth of 50–60 m.

16. x

Pre-MOD 3 dive checks

  • Diluent and all bailout gases analyzed (O₂, He) and labeled.
  • Hypoxic diluent clearly distinguishable.
  • Cells new, calibrated, linearity checked.
  • Scrubber fresh.
  • Written plan for each team member.

⚠ Labelling

Hypoxic gas cylinder must be clearly marked with minimum and maximum depth.

17. x

Gas switch plan

DepthGas
100–57 mBottom bailout 10/70
57–21 mTravel gas, e.g., 18/45
21–6 mEAN50
6–0 m100% O₂

Note

Specific gases and switch depths are determined by planning software, ICD rules, and instructor standards.

Self-check

Test yourself

What is the maximum depth for MOD 3?

What is the PO₂ of 10/70 at the surface?

What does the rule of fifths determine?

How much gas is consumed per minute at a depth of 100 m with a surface consumption of 25 l/min?

Summary

100 m

maximum depth

10/70

hypoxic diluent

3–5

bailout cylinders

Proceed to JJ-CCR MOD 3 Advanced Mixed Gas test →

This material supplements the official TDI course materials, the JJ-CCR manufacturer's operating manual, and instructor-led training, but does not replace them.