JJ-CCR MOD 2 – Mixed Gas / Trimix – theory

JJ-CCR MOD 2 · theory material

JJ-CCR MOD 2 – Mixed Gas / Trimix

Technical rebreather training up to 60 m with trimix diluent and multi-stage decompression

Navigate using buttons, arrow keys or by swiping with your finger. Slides include charts, interactive tools and self-assessment questions.

1. Introduction

What is MOD 2?

  • Max. depth: 60 m.
  • Diluent: normoxic trimix, e.g., 18/45 or 21/35.
  • Decompression: multiple stages, longer stops.
  • Bailout: bottom trimix and one or more deco gases.
  • Requirements: MOD 1 deco/Helitrox and experience according to agency standards.

CCR course depths

2. Gases

Diluent selection for 60 m depth

  • Diluent PO₂ at max. depth around 1.0–1.3 bar.
  • END usually ≤ 30 m.
  • Density ≤ 5.2 g/l, if possible.
  • Diluent must be breathable at the surface (O₂ ≥ ~16–18%).

18/45 at 60 m depth

ParameterValue
Diluent PO₂7 × 0.18 = 1.26 bar
END (N₂)≈ 23 m
Density≈ 5.6 g/l

3. Narcosis

END comparison at 60 m depth

  • Air at 60 m depth is not acceptable: severe narcosis and density.
  • 21/35: END ≈ 29 m.
  • 18/45: END ≈ 23 m.
  • More helium means a clearer head, but more expensive gas.

END 60 m (N₂ only)

4. Breathing

Gas density at 60 m

  • Air at 60 m: about 9 g/l, dangerously high.
  • 18/45: about 5.6 g/l.
  • High density increases the risk of CO₂ accumulation.
  • CCR loop resistance and scrubber exacerbate this.

Density at 60 m, g/l

5. Breathing

Fast descent and helium

  • A very fast descent with a lot of helium can cause tremors and HPNS symptoms.
  • At 60 m depth this is rare, but must be known.
  • A controlled descent also helps with ears and the loop.
  • When descending, watch the PO₂ increase.

Descent

Descent rate should be adjusted to the team and loop control, not just bottom time.

6. Bailout

Bailout configuration

  • Bottom bailout: trimix, e.g., 18/45 or 21/35.
  • Deco gases: EAN50 and/or 100% O₂.
  • Cylinders on the side (sidemount style) or on D-rings.
  • Each cylinder marked with MOD.
  • Bailout must be sufficient for the entire team at the critical point.

Bailout gases (illustrative)

7. Bailout

Bailout calculation for the entire dive

  • Bailout calculation is performed for the critical point: at the end of the bottom phase.
  • Calculate with stress consumption, e.g., 20–25 l/min.
  • Deco with open circuit is much longer than CCR.
  • Check if the bailout plan is executable in stages.

Deco time after 60 m dive (illustrative)

8. Decompression

Multistage decompression

  • First stops start deeper, according to GF.
  • Stops every 3 m.
  • Setpoint at stops: 1.2–1.3; at 6 m O₂ flush can be used.
  • Observe CNS and OTU limits.

Stop profile (illustrative)

9. Decompression

CNS and OTU for long dives

  • Long dives with a high setpoint increase CNS%.
  • Use a lower setpoint during the bottom phase if the dive is long.
  • In shallow stops, PO₂ can be increased.
  • Planning software shows CNS% and OTU.

Example

120 min at PO₂ 1.3 gives about 67% CNS. Adding O₂ stops, it can approach 100%.

10. Procedures

Bailout gas switch

1Reach MOD depth.
2Identify cylinder, read label.
3Buddy checks.
4Open valve, breathe from regulator.
5Switch the computer.
6Stow previous regulator.

⚠ Incorrect gas

Breathing gas with high O₂ deeper than its MOD can cause CNS convulsions. Breathing hypoxic gas at shallow depths can cause loss of consciousness.

11. Loop

Loop management at depth

  • During descent, ADV adds a lot of diluent.
  • Loop gas contains almost only diluent and O₂.
  • Diluent flush at 60 m: PO₂ ≈ 1.26 with 18/45.
  • O₂ flush at depth is dangerous: PO₂ > 1.6!

⚠ O₂ flush

Pure oxygen should only be flushed into the loop at 6 m or shallower.

12. Problem solving

Problem solving at depth

ProblemAction
Solenoid stuck openClose O₂ valve, control manually
Diluent cylinder emptyConnect from bailout with off-board connection
Cell failureDiluent flush for validation
CO₂ / waterBailout

Off-board gas

Bailout cylinders with QC connection can supply gas to the loop if the diluent cylinder runs out.

13. Team

Deep diving team

  • All team members know the bailout plan.
  • One bailout cylinder can be handed to a partner.
  • Turn points: time, gas, scrubber.
  • Support diver stops (deco team).

Principle

Team bailout gas is sufficient for at least one diver to return on open circuit.

14. Local practice

Deep wrecks in the Baltic

  • Many wrecks are located at a depth of 40–70 m.
  • Dark, cold water, currents.
  • In cold water, the scrubber performs worse.
  • Deco stop lines or DSMB.

Boat

The boat must have oxygen, a first aid kit, and communication with the shore.

15. Maintenance

Equipment after deep dives

  • Record scrubber time and depth.
  • Rinse the loop, disinfect, dry.
  • Check O-rings and one-way valves.
  • Check cell response and age.
  • Fill and analyze all gases.

Documentation

Record setpoint, gases, deco time, and issues in the dive log.

16. x

Pre-dive checks for MOD 2

  • Assembly according to checklist, pressure tests.
  • Cells calibrated and checked.
  • All gases analyzed (O₂ and He), marked with MOD.
  • Off-board connections checked.
  • All gases entered into computers.
  • Team briefing.

Briefing

Agree on turn points: time, bailout pressure, scrubber.

17. x

Setpoint strategy

  • Descent: low setpoint (0.7).
  • Bottom: 1.2–1.3, lower for long dives.
  • Deco: 1.3–1.4, observing CNS.
  • 6 m: O₂ flush up to 1.6, briefly.

Setpoint profile (illustrative)

Self-check

Test yourself

What is the maximum depth for MOD 2?

What is the PO₂ of 18/45 diluent at 60 m depth?

Where is O₂ flushing allowed?

Why is air not used at a depth of 60 m?

Summary

60 m

maximum depth

Trimix

diluent

Multi-deco

bailout gases

Sort JJ-CCR MOD 2 Mixed Gas test →

This material supplements the official TDI course materials, the JJ-CCR manufacturer's operating manual, and instructor-led training, but does not replace them.