JJ-CCR MOD 1 – Air Diluent Decompression – theory

JJ-CCR MOD 1 Deco · theory material

JJ-CCR MOD 1 – Air Diluent Decompression

Decompression diving with a rebreather to 40 m, using air as a diluent

Navigate using buttons, arrow keys or by swiping with your finger. Slides include charts, interactive tools and self-assessment questions.

1. Introduction

What is Air Diluent Decompression?

  • Max. depth: 40 m.
  • Diluent: air.
  • New: planned decompression stops.
  • Requirements: MOD 1 Air Diluent and CCR experience according to agency standards.
  • Prepares for MOD 1 Helitrox and MOD 2 courses.

Depth by courses

2. CCR and decompression

Why is CCR advantageous for decompression?

  • Constant PO₂ means optimal gas at every depth.
  • In the shallows, the inert gas fraction is lower than in open circuit.
  • Shorter decompression than with air in open circuit.
  • Low gas consumption: deco time does not empty cylinders.

Inert gas fraction at PO₂ 1.3 (illustrative)

3. Decompression

Decompression basics

  • Tissues absorb nitrogen proportionally to its partial pressure.
  • When ascending, gas must be allowed to release in a controlled manner: stops.
  • Use an algorithm, e.g., Bühlmann with gradient factors (GF).
  • Conservative GF, e.g., 30/70 or 40/80.

What does GF 30/70 mean?

The first stop starts at 30% of the M-value, at the surface 70% is allowed. Smaller numbers mean a more conservative plan.

4. Physiology

Narcosis and density at 40 m depth

  • With air diluent, the END at 40 m depth is almost 40 m.
  • Narcosis affects decision-making and problem-solving.
  • Gas density for air at 40 m is about 6.4 g/l, exceeding the recommended 5.2 g/l.
  • Therefore, 40 m is the limit for air diluent.

Air density, g/l

5. Planning

Dive plan

  • Depth, bottom time, setpoint, GF.
  • Decompression schedule and its backup plan.
  • Scrubber used time and remaining time.
  • Bailout gas for decompression if the loop fails.
  • Team communication and decision points.

Plan with a reserve

Take two schedules with you: CCR plan and open-circuit bailout plan. Bailout deco is always longer.

6. Planning

Scrubber duration

  • Use the manufacturer's specified scrubber time and reduce it in cold water.
  • Keep track of the time used for each dive.
  • Decompression diving extends the total time.
  • Never plan a dive that exceeds the remaining time.

Scrubber time (illustrative)

7. Bailout

Bailout decompression

  • Bailout gas must be sufficient for both ascent and stops.
  • Open-circuit decompression with air is longer.
  • Often two cylinders are used: bottom bailout and deco gas (e.g., EAN50).
  • Bailout cylinders must be carried with you, not left on the line.

Deco time: CCR vs bailout (illustrative)

8. Bailout

Bailout to deco gas

1Check depth and MOD.
2Identify cylinder and regulator.
3Buddy confirms.
4Close DSV, breathe from regulator.
5Switch computer to open circuit.

EAN50 MOD

At PO₂ 1.6: 1.6 / 0.5 = 3.2 bar, so 22 m. Use 21 m or shallower.

9. Stops

Loop management at stops

  • Maintain precise depth: ascending at stops changes PO₂.
  • Usually at shallow depths the setpoint remains high (1.2–1.3).
  • At 6 m depth, oxygen flush can be used to accelerate deco.
  • During the last stop, check bailout and SMB.

O₂ flush at 6 m

With pure oxygen at 6 m depth, PO₂ is 1.6 bar. Keep flush short and monitor CNS load.

10. Physiology

Oxygen exposure

  • Track CNS% and OTU.
  • Long bottom time with high setpoint increases CNS.
  • Limit CNS to around 80% within a single day.
  • The computer calculates this, but understand how.

CNS% per minute at PO₂

11. Ascent

DSMB and ascent

  • Deploy DSMB from the first stop or bottom.
  • During deployment, control the loop and buoyancy.
  • Ensure the reel does not tangle around the equipment.
  • Ascend according to the plan, checking PO₂.

⚠ Attention

When inflating the DSMB with loop gas, the loop volume decreases and diluent may be added. Monitor PO₂.

12. Problem solving

Common problems

ProblemAction
High PO₂Diluent flush, check solenoid
Low PO₂Add O₂ manually, check O₂ cylinder
Cell disagreementDiluent flush and check
Signs of CO₂Bailout
Flooded loopBailout

Principle

If the problem cannot be solved quickly and safely, switch to open circuit and terminate the dive.

13. Troubleshooting

Controller failure

  • JJ-CCR can also be operated manually (in mCCR mode).
  • Manually add O₂ to maintain PO₂.
  • If there is no reliable PO₂ reading, switch to bailout.
  • Backup computer for deco information.

Backups

Two independent PO₂ readings (e.g., wrist computer and HUD) are the minimum requirement.

14. Team

Team diving

  • Agree on the plan and signals before the dive.
  • Know your buddy's bailout configuration.
  • If one buddy switches to bailout, both must terminate the dive.
  • Gas sharing: bailout cylinders can be handed to a buddy.

Signals

Agree on signals for "PO₂ high", "PO₂ low", "bailout" and "CO₂".

15. Local practice

CCR diving in the Baltic

  • Cold water reduces scrubber efficiency.
  • Wrecks at 30–40 m depth are ideal for this course.
  • Warm and moist loop gas reduces heat loss.
  • Oxygen and communication must be available on the boat.

Recommendation

In cold water, use reserve scrubber time and drysuit heating.

16. Maintenance

After diving

  • Log the scrubber usage time.
  • Rinse the counterlungs and mouthpiece, disinfect.
  • Check for water in the loop.
  • Unload and store sensors correctly.
  • Fill O₂ and diluent cylinders.

Disinfection

Use the agent recommended by the manufacturer. The loop is moist and warm, so bacteria multiply easily in it.

17. Planning

Deco dive checks

  • Full assembly and pressure test check.
  • Cells calibrated, pre-breathe 3–5 min.
  • Bailout and deco gases analyzed and marked.
  • GF, diluent and bailout gases entered into computers.
  • Remaining scrubber time is sufficient with a reserve.
  • Team briefing: plan, signals, decision points.

Briefing

Before every deco dive, the team agrees on the maximum depth, bottom time, and actions in case of bailout.

Self-check

Test yourself

What is the maximum depth for Air Diluent Decompression?

Why is 40 m the limit for air diluent?

What is the MOD of EANx50 at a PO₂ of 1.6?

What happens to the deco time if you have to switch to bailout?

Summary

40 m

maximum depth

GF

conservative plan

Bailout

deco gas

Take the JJ-CCR Air Diluent Decompression test →

This material supplements the official TDI course materials, the JJ-CCR manufacturer's operating manual, and instructor-led training, but does not replace them.